Mean Well HVG-100 Series LED Driver 100W 15-54V

In stock
SKU
HVG-100-S

Built-in 3 in 1 dimming function (0~10VDC, PWM signal, or resistance)

Wide input range: 180~480VAC

Protections: Short circuit / Over voltage / Over temperature

Other features:

  • High efficiency up to 92%
  • Built-in active PFC
  • Cooling by free air convection
  • C.V. + C.C. mode design
  • Output current adjustable through output cable or internal potentiometer
  • Suitable for dry, damp and wet locations
  • Suitable for LED lighting and street lighting applications
  • IP67 design
  • 5 years warranty
Grouped product items
HVG-100-15A HVG-100-15B HVG-100-20A HVG-100-20B HVG-100-24A HVG-100-24B HVG-100-30A HVG-100-30B HVG-100-36A HVG-100-36B HVG-100-42A HVG-100-42B HVG-100-48A HVG-100-48B HVG-100-54A HVG-100-54B
Wattage 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Input Voltage (V) 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC 180~480VAC, 254~679VDC
Output Current (A) 0~5.0 0~5.0 0~4.8 0~4.8 0~4.0 0~4.0 0~3.2 0~3.2 0~2.65 0~2.65 0~2.28 0~2.28 0~2.0 0~2.0 0~1.77 0~1.77
Output Voltage (V) 15 15 20 20 24 24 30 30 36 36 42 42 48 48 54 54
Output Voltage Options Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single Single
DC output adjustment +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage +/-10% rated output voltage
Working Temperature -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40~+70°C -40~+70°C -40~+70°C -40~+70°C -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve") -40 ~ +70°C(Refer to "Derating Curve")
Safety Standards Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13 Design refer to UL8750, TUV EN61347-1, EN61347-2-13
EMC Standards Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547 Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Dimensions (LxWxH) mm N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
More Information
Wattage 100
Input Voltage (V) 180~480VAC, 254~679VDC
Output Current (A) 0~1.77
Output Voltage (V) 54
Output Voltage Options Single
DC output adjustment +/-10% rated output voltage
Working Temperature -40 ~ +70°C(Refer to "Derating Curve")
Safety Standards Design refer to UL8750, TUV EN61347-1, EN61347-2-13
EMC Standards Design refer to EN55015, FCC part 15 class B, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, EN61547
Packaging 12pcs/15.2Kg
Mean Well HVG-100 Series LED Driver 100W 15-54V listed in 0-10V category. Save on Mean Well LED Driver - SKU: HVG-100-S. Pricing & Availability on request. Please call 01844 20 44 20 or email info@ecopacpower.co.uk
Write Your Own Review
You're reviewing:Mean Well HVG-100 Series LED Driver 100W 15-54V