Mean Well LED Driver HVGC-320 Series 300-320W 700-2500mA

In stock
SKU
HVGC-320-S

Wide input range 180~528VAC

High efficiency up to 91%

Built-in active PFC function

Protections: Short circuit / Over current / Over voltage / Over temperature

Other features:

  • Constant current design
  • Cooling by free air convection
  • Output voltage and CC level can be adjusted through internal potentiometer
  • IP65 design for indoor or outdoor installations
  • Suitable for LED lighting and street lighting applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp / wet locations
  • 5 years warranty
Grouped product items
HVGC-320-1050A HVGC-320-1050B HVGC-320-1400A HVGC-320-1400B HVGC-320-1750A HVGC-320-1750B HVGC-320-2100A HVGC-320-2100B HVGC-320-2800A HVGC-320-2800B HVGC-320-3500A HVGC-320-3500B HVGC-320-700A HVGC-320-700B
Wattage 320 320 320 320 320 320 320 320 320 320 320 320 300 300
Input Voltage (V) 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC 180~528VAC 254VDC~747VDC
Output Current (A) N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Output Voltage (V) 152.4~304.8 152.4~304.8 114.3~228.6 114.3~228.6 91.4~182.8 91.4~182.8 76.2~152.4 76.2~152.4 57~114.3 57~114.3 45.7~91.4 45.7~91.4 214~428 214~428
Output Voltage Options Single Single Single Single Single Single Single Single Single Single
DC output adjustment N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
Working Temperature Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve") Tcase=-40~+90???C (Refer to "Derating Curve")
Safety Standards UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved
EMC Standards Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A
Dimensions (LxWxH) mm 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8 262x 90x 43.8
More Information
Wattage 300
Input Voltage (V) 180~528VAC 254VDC~747VDC
Output Voltage (V) 214~428
Output Voltage Options Single
Working Temperature Tcase=-40~+90???C (Refer to "Derating Curve")
Safety Standards UL8750 (type ???HL???), CSA C22.2 No. 250. 13-12, IP65 or IP67 approved
EMC Standards Compliance to FCC Part 15 Subpart B, EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (Surge immunity Line-Earth 4KV, Line-Line 2KV) Criteria A
Dimensions (LxWxH) mm 262x 90x 43.8
Packaging 8pcs/17.2Kg

Constant current design

Wide input range 180~528VAC

Three in one dimming function (0~10Vdc or 10V PWM signal or resistance)

Protections: Short circuit/ Over current/ Over voltage/ Over temperature

Other features:

  • Built-in active PFC function
  • High efficiency up to 93.5%
  • Cooling by free air convection
  • IP67/IP65 design for indoor or outdoor installations
  • Function options: output adjustable via potentiometer
  • Typical lifetime >50000 hours
  • 5 year warranty