Mean Well Power Supply DDR-120 Series 120W 99.6-120V

£10.00

Availability: In stock

DDR-120-S

Can be installed on DIN rail TS-35/7.5 or 15

Protections: Short circuit/ Overload/ Over voltage/ Input reverse polarity/ Input under voltage protection

Other features:

  • Compliance to EN50155 and EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • 4KVdc I/O isolation (Reinforced isolation)
  • -40~+70°C wide working temperature
  • 3 years warranty

* Required Fields

£10.00
  • Series Products
  • Modifications

Technical Specifications

DDR-120A-12DDR-120A-24DDR-120A-48DDR-120B-12DDR-120B-24DDR-120B-48DDR-120C-12DDR-120C-24DDR-120C-48DDR-120D-12DDR-120D-24DDR-120D-48
Wattage 99.6 100.8 100.8 120 120 120 120 120 120 120 120 120
Output Current (A) 0-8.3A 0-4.2A 0-2.1A 0-10A 0-5A 0-2.5A 0-10A 0-5A 0-2.5A 0-10A 0-5A 0-2.5A
Output Voltage (V) new 5 24 48 5 24 48 5 24 48 5 24 48
Output Voltage Options Single Single Single Single Single Single Single Single Single Single Single Single
DC output adjustment 9-14V 24-28V 48-56V 9-14V 24-28V 48-56V 9-14V 24-28V 48-56V 9-14V 24-28V 48-56V
Working Temperature -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C -40°C-+70°C
Safety Standards IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508 IEC 62368-1 (LVD) approved, Design refer to UL508
EMC Standards Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8 Compliance to EN55032, EN61000-3-3. Compliance to EN55024, EN61000-6-2 (EN50082-2), EN61000-4-2,3,4,5,6,8
Powered by MeanWell Logo

 

We have many years of experience modifying and designing bespoke power supply solutions. Our highly trained, expert team offer a full range of modification services to any of our products. If you have custom power supply requirements we can help. We offer custom solutions including conformal coating, re-boxing, changing connectors, on board component changes and more.

Call us today to discuss your requirements on 01844 20 44 30 and speak to one of technical team. If you prefer you can send us an email with your requirements by clicking here